显示标签为“electri cenergy meter”的博文。显示所有博文
显示标签为“electri cenergy meter”的博文。显示所有博文

2013年12月22日星期日

Power supply voltage is higher than the rated voltage transformer, the transformer itself and its load will have adverse consequences

If the supply voltage is higher than the rated voltage of the transformer, the transformer itself and its load will have adverse consequences. Typically, the transformer  electri cenergy meter  at rated voltage, the magnetic flux density in the core close to saturation. If the supply voltage is higher than the rated voltage, the excitation current will rapidly increase, the power factor decreases. In addition, the voltage is too high and may burn out the transformer windings. When the power supply voltage 105 exceeds the rated voltage, the waveform of the potential  power transformers  large distortion occurs, it contains more high-order harmonic component, the maximum potential will increase, causing damage to the winding insulation. On the other hand, the supply voltage is too high, the output voltage of the transformer will increase accordingly, which will not only lead to electrical equipment overload, over-voltage, but also reduce the life of electrical equipment, even when serious breakdown of insulation, burn bad equipment.

2013年10月18日星期五

Transformer fault diagnosis, there is a large number of expert experience

With the continuous development of the electricity market, people on the reliability of power supply put forward higher requirements, which requires electricity to run the department as soon as possible from planned maintenance to condition-based  electri cenergy meter  mechanism to changes in the mechanism. In recent years, with the oil chromatographic analyzer successful development of online and digital signal processing technology and other related areas of continuous development  mcb circuit breaker , making this  circuit breakers  possible. In transformer fault diagnosis, there is a large number of expert experience, it is difficult to establish a precise mathematical model. The expert system was able to effectively solve this kind of problem, the information is incomplete or uncertain circumstances, still be able to give a more reasonable conclusion.

Digital signal processing technology and other related fields of continuous development and improvement

In recent years, with the oil chromatographic analyzer successful development of online and digital signal processing technology and  Voltage stabilizer  fields of continuous development and improvement, to make this change possible.  In the transformer fault diagnosis, there are a lot of expert experience, it is difficult to establish a  electri cenergy meter  model. The expert system was able to effectively solve this kind of problem, the information is incomplete or uncertain circumstances, still be able to give a more reasonable conclusion. Therefore, this paper  power transformers  of a large number of original features obtained through online data, the paper introduces a rule-based production method as a knowledge representation, the choice of forward chaining inference mechanism.

2013年10月10日星期四

Complete packaging container inspection system electronic control thermostat Stacking detection equipment on the basis of written

Upon completion of the packaging container inspection system electronic control thermostat Stacking detection equipment on the basis of written. At present, the packaging  electric transformer  production and export commodities inspection and testing of packaging containers, loaded by hand stacking method, load it backward technology, labor-intensive, low detection electri cenergy meter , no longer meet the economic development needs of testing equipment. In order to change the packaging container load detection methods to improve the detection level of control technology, we have taken with the cylinder loaded with PLC programmable controller for automatic detection and control of the new method, and use their computer network communications.

Thermal environment wind tunnel test is assessing ground theoretical calculation method to provide a basis for the anti-thermal design an important means of

Thermal environment wind tunnel test is assessing ground theoretical calculation method to provide a basis for the anti-thermal design an important means. Ground testing of measuring heat directly affects the accuracy of calculation methods and the selection of anti-thermal structure, is to determine whether or not the key factor in the success of  electri cenergy meter . Film resistance thermometer as the most common shock tunnel heat flux measurement sensors, trial staff from the sensor production, calibration, installation, data acquisition system aspects such as the sampling  electric meter  to improve measurement precision thermal test. In fact, the film resistance thermometer in the test measured voltage information (ie, temperature variation), but also through theoretical analysis and calculation the temperature information into heat flow values.

2013年10月8日星期二

Often help the life of electronic components working condition, but by storing to determine damage caused by

In laboratory and field applications of electronic components in a variety of conditions, operational reliability has been a lot of work, but also published a lot of information. However, in the military utility when the life of electronic components often determined not by working status, but the damage caused by the store to decide.  electri cenergy meter store one year, five years or even ten years. After storage, these devices must immediately be able to work properly. And some equipment has been  mcb circuit breaker  their useful life, in fact, electronic components, the life time of the long-term storage tests are difficult to implement, because: 1. Was not enough time to do such tests. 2 is expected to be less efficient storage failure (failure rate of about 0.01 to work 0.1), therefore, failure to obtain a variety of practical efficiency (with small statistical errors), then the required number of test samples. If you can find a reasonable accelerated test method, not only shorten the test time, but also reduce the cost of evaluation of the effect of storage devices. Storage environment to define various conditions must be manufactured from the elements until the beginning of the end of useful life are taken into account.

Coil current transformer is more of an active type of electronic current transformers

Coil current transformer is more of an active type of electronic current transformers. Its general use sensor head coil, with good linearity, insulation, simple structure, no security risks, non-core, non-magnetic saturation phenomenon,  air circuit breaker  bandwidth and accuracy and other fine features, so it has been widely used. However, due to the coil output electromotive force is proportional to the time derivative of the measured current to recover with a current signal  electri cenergy meter  the integral must add the appropriate link. Currently, the integral part of the low-frequency noise, voltage drift and phase response of the integrator is the impact of electronic current transformer low frequency low current measurement accuracy of the main reasons. This paper describes the use of several integrator for their advantages and disadvantages are analyzed and discussed, and the design of digital integrator, laboratory tests show that the method is effective and practical.

Maturing photoelectric transformer instead of the traditional electromagnetic transformer

The use of increasingly sophisticated photoelectric transformer instead of the traditional electromagnetic transformer, power grid construction and transformation to achieve far-reaching significance. Straight people hot topic. In  electri cenergy meter , the temperature variation errors of measurement, one should increase the optical system (such as the light source, optical, electro-optical crystal) and a photodetector (such as a photodiode) of the anti-jamming capability, such as  Voltage stabilizer and a small light source wavelength shift, pure and after several electro-optic crystal pulling and so on. Also in the temperature stability of the study, scholars much attention recently with temperature control method, two optical temperature compensation method, two crystal temperature compensation circuit compensates for hardware and software compensation method.

Optical voltage transformer developed countries photoelectric current voltage transformer sensing methods can be divided into two kinds of active-and passive

Optical voltage transformer developed countries photoelectric current voltage transformer sensing methods can be divided into two kinds of active-and passive. Active type active high side voltage signal by  electri cenergy meter  signal is passed in.  Voltage stabilizer  signal to the light emitting diode, and then transmitted from the optical fiber to the low potential side, into an electrical signal for the inverter output after amplification. The luminous intensity of the diode is proportional to the applied voltage, the signal output is proportional to the applied voltage. Study how the photoelectric transformer substation automation system interface and communication, the realization of photovoltaic substation digitization will be of great significance.

2013年9月23日星期一

Method using hardware and functional method to divide power transformer composition

The risk of failure and status maintenance decision methods and other key issues in-depth study: ① power  electric meter  failure modes and effects analysis. Power transformer on the structure and function of depth and detailed analysis, based on the method of using a combination of hardware and functional method for power transformer  electri cenergy meter  is divided, and then the various components of all possible failure modes and effects of in-depth analysis, to avoid a complete according to the system structure failure mode and effects analysis of the complexity of the transformer reliability and fault risk assessment basis. ② based on multi-characteristic parameters of the power transformer fault probability comprehensive evaluation method.

With several volts to 100 volts high voltage conversion ratio of the boost converter

Piezoelectric actuator (piezoeieetric Actuator) because of its compact size and high resolution displacement is widely used in a variety of applications, especially in the smart phone / camera modules of the application more popular. The application of the mobile device, while the existing power supply is a low battery, but still high driving voltage driving the piezoelectric actuator in order to electric transformer performance mobile phone many applications, so it is necessary to use a few volts to 100 volts high voltage conversion ratio of the boost converter. Traditional boost DC to DC (DC a DC) converter or a boost converter is not suitable for electri cenergy meter  where a high voltage conversion ratio, since the boost inductor equivalent series resistance (ESR), disables the output  electric meter  is higher than the input voltage is increased by 10-fold above. This article describes the coupled inductors with high boost DC-DC converter, with an indication of its working principle and design considerations. There boost inductor equivalent series resistance continuous conduction mode voltage conversion ratio.

Transformer losses and operating costs between

Necessary to use a start of pumping with a large capacity, in the normal operation pumping unit has a small capacity, the capacity can be adjusted for the modulation capacity transformer. The project studied load transfer capacity of the transformer principle is the use of  power transformers capacity and loss of the relationship electri cenergy meter the transformer losses and the relationship between the running costs, from the "road" point of view, the use of the time-domain equivalent sine wave the equivalent circuit method and frequency-domain equivalent circuit combination form of time domain - frequency domain method is applied to the transformer characteristics of deduced load transfer capacity of the transformer magnetic circuit model and the model.

Left a large distribution transformer capacity margin

For pumping the load carried by the distribution transformer, the maximum load torque at the start, the maximum output power distribution transformer, the starting period of time, the load torque becomes smaller, the output power distribution  electri cenergy meter  is greatly reduced. Therefore, in order to meet the requirements of pumping starter, left a large  Voltage stabilizer  transformer capacity margin. The transformer load is low rate of long-term working status, resulting in a waste of transformer capacity and active and reactive power losses, reducing the efficiency of the transformer, increasing the net loss for the reduction to the pumping power distribution transformers losses.

Component parts include: transformer winding (Dyn11, Yyn0) the body, the cabinet housing

Combined Transformer is the body of the transformer, switchgear, fuses, tap combination and the corresponding auxiliary equipment transformers, also known as box-type transformer in the country also known as American box. Its constituent parts, including:  electri cenergy meter  winding (Dyn11, Yyn0) the body, box casing, inlet and outlet tube wells, connecting leads, load switch, back-up fuse, insert the fuse,  mcb circuit breaker  indicating instrument, tap, low outlet terminals, low-voltage circuit breakers, compensation capacitors, high voltage cable accessories. As most of the lead parts are installed in the transformer tank, and its connection to the tank after running process determines whether there is the possibility of oil leakage, although manufacturers in the box transformer factory have adopted strict process measures, but due to put into operation site conditions vary, connecting parts of the oil leakage situation occur, the author personally come into contact with several oil leakage and treatment methods to do a detailed introduction.

The frequency signal through power electronic circuits into a high-frequency signal

Power transformer is mainly used in power electronics technology, the basic principle is the power frequency signal through power electronic circuits into a high-frequency signal, ie upscaling and high frequency isolation transformer coupling  electri cenergy meter , and then restore the frequency signal, the reduced frequency. By using appropriate control programs to control the operation of the device power  air circuit breaker , which will one frequency, voltage, power conversion waveform to another frequency, voltage, power waveform. The volume of the intermediate isolation transformer core material depends on the saturation magnetic flux density and the winding core and the maximum allowable temperature rise.

2013年9月17日星期二

Dry type transformer coil encapsulated and non-encapsulated coil and two kinds of dry-type transformers

In the current network reconstruction and urban network planning, the dry-type transformer resin and filler (mainly quartz sand) casting, so-called thick excellent performance is its unique and widely used. Insulation; C. Glass fiber reinforced epoxy resin casting, GB6450-86 provides that measures core dry-type transformers and lines is called a thin insulating structure towel, multi-strand glass fiber impregnated with epoxy resin ring is not  Circuit breaker  in an insulating liquid a  electri cenergy meter  winding in the structure of fat and other four. Currently most of the countries and regions in the world can be divided into dry type transformer coil encapsulated and non-encapsulated dry-type transformers and coils are two main  power transformers  between the two products although somewhat in the shape junction area with solid insulation will coil encapsulated, this article focuses on a ring types, are structured in the form of coils only epoxy resin encapsulated dry-type transformers are reviewed. High voltage winding (10 ~ 36kV) or impregnated epoxy resin cast dry-type transformers, referred to generally cylindrical multi-layer or multi-layer sub-structure;

Electrified railways cast resin dry-type transformers

Vacuum casting resin insulation dry-type transformers are using new insulating materials and advanced technology production of a new transformer, because of its high adaptation filthy, hot, humid environment, flame retardant, fire, pollution, etc., are called energy type,  electric meter  protection, disaster prevention transformer, widely used at home and abroad. In order to develop suitable for China 275kV  electri cenergy meter  railways cast resin dry-type transformers. Through analysis that electrified railway transformer 275kV most characteristic and representative of traction substation, partitioning kiosks and other premises used for transformer, so make sure to start from the transformer research to develop a relevant  air circuit breaker  and technical specifications. 1999 completed three single-phase prototype design, manufacturing and various tests. Respectively, in Longhai line Yaocun partition kiosks and traction substation east of Xi'an, Baoji-Chengdu line Swallow acupuncture traction substation put into trial operation, normal operating conditions are safe.

Do not connect with the external atmosphere, can be used in a more hostile environment

Without insulating oil of the transformer. By type are: ① open type, which is connected with the atmosphere through the body, suitable for clean and relatively dry indoor environment; ② closed, the body has a closed shell, so that do not connect with the external  electri cenergy meter , can be used more hostile environment; ③ mastic, epoxy or other resin casting as insulation, its small size, light weight, easy to install, easy to maintain, no fire and explosion hazard, suitable for high-rise  circuit breakers , subways and other fire safety requirements of high place. Conditions of use of the product, in addition to the general requirements of the same transformer, it must also be installed in a well-ventilated place.

General control circuit components required more significant number of contacts

Using relays, contactors and other control buttons on electrical motors or other electrical equipment on or off automatic control system, called the relay contactor system. It is widely used in machining control, power transmission and distribution system, elevator control, and air conditioning and refrigeration equipment control and so on. Because the system is by controlling the state of the contact element and that a logical relationship, it is generally required many components of the control circuit, a large number of contacts. This characteristic to the line maintenance caused great difficulties. I work in practice summed up a set method --- relay contactor control system functions chain  electri cenergy meter and troubleshooting chart column method. Are presented below for reference. Relay  circuit breakers system functions chain control system wiring diagram is a schematic representation, in accordance with component action sequence, indicating that the control circuit functions chain diagram. It clearly reflects the control lines and achieve functional correspondence between, helps to understand the working principle of control lines to help control the line maintenance and troubleshooting.

A direct impact on production efficiency and production efficiency

The main role of relay control circuit for the production of mechanical services, is the production machinery in the production process an important and indispensable component. In automatic production lines or machine control using relay control many of the electrical control circuit, the actual production, relay control  mcb circuit breaker  is reliable, reasonable, stable, and a direct impact on production efficiency and production efficiency. We engaged in maintenance electrician school-enterprise  electri cenergy meter  and practical teaching skills training process, found that many students and trainees, and even a lot of actual production experienced front-line electrician, how to design a reasonable aspects relay control circuit exists over large gaps.