2013年12月22日星期日

Power supply voltage is higher than the rated voltage transformer, the transformer itself and its load will have adverse consequences

If the supply voltage is higher than the rated voltage of the transformer, the transformer itself and its load will have adverse consequences. Typically, the transformer  electri cenergy meter  at rated voltage, the magnetic flux density in the core close to saturation. If the supply voltage is higher than the rated voltage, the excitation current will rapidly increase, the power factor decreases. In addition, the voltage is too high and may burn out the transformer windings. When the power supply voltage 105 exceeds the rated voltage, the waveform of the potential  power transformers  large distortion occurs, it contains more high-order harmonic component, the maximum potential will increase, causing damage to the winding insulation. On the other hand, the supply voltage is too high, the output voltage of the transformer will increase accordingly, which will not only lead to electrical equipment overload, over-voltage, but also reduce the life of electrical equipment, even when serious breakdown of insulation, burn bad equipment.

There are so many pebbles under the transformer resolved

Prevent oil spills, but also fire riot. Seepage of oil can go on, as if the provisions of the ministerial standards, a large oil-immersed transformers shall be provided with the lower oil reservoir, an area   Electric transformer  than the plane occupied by the transformer, the depth of about 1M, laying 10CM diameter around the cobbled   air circuit breaker  is to absorb the transformer oil. But let not the oil can absorb the oil leak continues, the transformer is a slope below the lowest point has a grille, through tubing connected to the incident under the tank. Let go of the oil flow to the accident on the tank!

There are so many pebbles under the transformer resolved

Prevent oil spills, but also fire riot. Seepage of oil can go on, as if the provisions of the ministerial standards, a large oil-immersed transformers shall be provided with the lower oil reservoir, an area   Electric transformer  than the plane occupied by the transformer, the depth of about 1M, laying 10CM diameter around the cobbled   air circuit breaker  is to absorb the transformer oil. But let not the oil can absorb the oil leak continues, the transformer is a slope below the lowest point has a grille, through tubing connected to the incident under the tank. Let go of the oil flow to the accident on the tank!

There are so many pebbles under the transformer resolved

Prevent oil spills, but also fire riot. Seepage of oil can go on, as if the provisions of the ministerial standards, a large oil-immersed transformers shall be provided with the lower oil reservoir, an area  Voltage stabilizer  than the plane occupied by the transformer, the depth of about 1M, laying 10CM diameter around the cobbled  power transformers  is to absorb the transformer oil. But let not the oil can absorb the oil leak continues, the transformer is a slope below the lowest point has a grille, through tubing connected to the incident under the tank. Let go of the oil flow to the accident on the tank!

2013年12月1日星期日

Work features intelligent AC contactor: intelligent AC contactor on the switch body

Work features intelligent AC contactor: intelligent AC contactor on the switch body, the installation of intelligent control module, starting, pull, breaking the optimal control of the whole process, and having a communication function in the starting process, the microcontroller  air circuit breaker . voltage real-time sampling, if the supply voltage exceeds the minimum pull-in voltage, the voltage value according to the SCM system in accordance with the appropriate procedures to control the controllable elements phasing, timing of work to ensure that the contact is in the best starting state in sorption state, low voltage Sorption DC circuit provides the electrical energy to achieve energy sorption silent operation.  mcb circuit breaker , breaking signal, microcontroller system through the current transformer on the main circuit current is sampled to enter the three-phase circuit breaking  Circuit breaker  control procedures to achieve breaking control the intelligent AC contactor has the following salient features: to achieve a zero-phase circuit breaking current control, no arc or less arc breaking, contactors electrical life greatly improved; through the SCM process control, corresponding to different supply voltages, contactors You can select the best closing phase angle, with the election phase closing function;

Vacuum breaker power transmission and distribution systems as the most common switch electrical equipment

Vacuum breaker power transmission and distribution systems as the most common switch electrical equipment, its mechanical  electric transformer  is necessary, but also improve the supply and distribution reliability, the only way to protect the safety of the power system. The overall design of the mechanical properties of the vacuum circuit  Voltage stabilizer  of the system mainly refers to mechanical actuation device driven dynamic and static contact points closing process, some of the performance indicators, the main trip contact stroke of closing speed, average speed of closing , open and close time, over the same period of the three-phase tripping, closing contacts average speed, closing contact bounce time, the cumulative movement allowed to wear contacts thickness.

Reliability of the vacuum circuit breaker depends to a large extent the mechanical actuating system reliability

Reliability of the vacuum circuit breaker depends largely on the mechanical reliability of the actuator system. International Conference organized international survey shows that a large grid in a vacuum circuit breaker failure, mechanical failure (including the actuator and control circuit) accounted for more than four-fifths of all the failures, other arcing, insulation faults occupy a smaller proportion lower heat failure ratio.  Voltage stabilizer  factory inspection and  electric meter  test users, regarded as an important test of the mechanical properties of the pilot project. Based on the analysis of research results and trends on the domestic circuit breaker monitoring, developed the mechanical properties of the vacuum circuit breaker testing device based on DSP. First, the mechanical  power transformers  of the vacuum circuit breaker test parameters were analyzed, and then introduces the mechanical properties of the vacuum circuit breaker test equipment hardware and software design, hardware design. Firstly, the instantaneous signal responsive to the Hall current sensor actuator aggregate, the current signal tripping coil; using linear displacement sensors measure the moving contact trip signal, and converts it into a voltage signal synchronization output;